Manual Mdi/Mdix Setting; Link Speed Downshift - Renesas R-IN32M4-CL2 User Manual

Gigabit ethernet phy edition
Hide thumbs Also See for R-IN32M4-CL2:
Table of Contents

Advertisement

R-IN32M4-CL2 User's Manual Gigabit Ethernet PHY Edition
2.1.4

Manual MDI/MDIX Setting

As an alternative to HP Auto-MDIX detection, the PHY can be forced to be MDI or MDI-X using register 19E1, bits 3:2.
Setting these bits to 10 forces MDI and setting 11 forces MDI-X. Leaving the bits 00 enables the HP Auto-MDIX setting
to be based on register 18, bits 7 and 5.
2.1.5

Link Speed Downshift

For operation in cabling environments that are incompatible with 1000BASE-T, the GbE-PHY provides an automatic
link speed downshift option. When enabled, the device automatically changes its 1000BASE-T autonegotiation
advertisement to the next slower speed after a set number of failed attempts at 1000BASE-T. No reset is required to get
out of this state when a subsequent link partner with 1000BASE-T support is connected. This feature is useful in setting
up in networks using older cable installations that include only pairs A and B, and not pairs C and D.
To configure and monitor link speed downshifting, set register 20E1, bits 4:2. For more information, see Table 3.33
ActiPHY Control, Address 20E1 (0x14).
R18UZ0043EJ0100
Mar 4, 2016
2. Functional Descriptions
Page 4 of 39

Advertisement

Table of Contents
loading

This manual is also suitable for:

R9j03g019gbg

Table of Contents