All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp.
Page 2
Renesas Electronics disclaims any and all liability for any damages or losses incurred by you or any third parties arising from the use of any Renesas Electronics product that is inconsistent with any Renesas Electronics data sheet, user’s manual or other Renesas Electronics document.
Page 3
Terms and Conditions available at https://www.renesas.com/en-us/legal/disclaimer.html. The TB-S1JA is not guaranteed to be error free, and the entire risk as to the results and performance of the TB-S1JA is assumed by the User. The TB- S1JA is provided by Renesas on an “as is” basis without warranty of any kind whether express or implied, including but not limited to the implied warranties of satisfactory quality, fitness for a particular purpose, title, and non-infringement of intellectual property rights with regard to the TB-S1JA.
Target Board Kit S1JA (TB-S1JA) 1. Overview The Target Board Kit S1JA (TB-S1JA) enables developers get started with initial firmware development and evaluation of the Synergy Software Package (SSP) on the S1JA MCU Group. • Renesas Synergy™ S1JA Microcontroller Group ...
Page 7
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Figure 1. TB-S1JA Top Side R12UM0025EU0101 Rev.1.01 Page 4 of 31 Apr.21.20...
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Figure 2. TB-S1JA Bottom Side 2. Kit Contents The following components are included in the Target Board Kit (TB-S1JA): • 1x TB-S1JA board • 1x USB Type-A to USB Micro-B cable R12UM0025EU0101 Rev.1.01 Page 5 of 31 Apr.21.20...
Note: The TB-S1JA uses J-Link On-board (OB) debug interface. While J-Link drivers are necessary to establish debug connection between the host PC and the TB-S1JA, they are not required to run the Out-of-Box (OoB) Demonstration (Blinky) Application that the TB-S1JA comes pre-programmed with.
Figure 3. Copper Jumpers 4.1.2 Default Board Configuration The following table describes the default settings for each jumper on the TB-S1JA Target Board. This includes traditional pin jumpers (Jx designation) and copper jumpers (Ex designation.) The Circuit Group for each jumper is the designation found in the board schematic. Functional details for many of the listed jumpers may be found in Section 4.4, Connectivity and Settings, and section 4.6,...
Page 11
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Location Circuit Group Default Function Open/Closed Capacitive Touch Closed Enable/Disable Capacitive Touch Button Button (connects P001 on MCU to Capacitive Touch Button) Open Connects P001 on MCU to J2-20 EXT VCL and VCL CAP Open...
Figure 4. TB-S1JA Block Diagram 5.2 Power Requirements TB-S1JA is designed for 3.3 V operation. This also means that 5 V PMOD devices cannot be used together with the TB-S1JA unless they are powered separately. The total current available from the LDO regulator for all connected circuits is 600 mA or less, depending on the 5 V power source used.
5.2.1.2 Option 2: Test Points TP3 and TP4 TB-S1JA can also be powered by installing a 5 V power source across TP3 (positive input) and TP4 (negative input). Copper jumper E35 must be opened to enable powering the board using these test points.
Page 14
J4 (pin J4-37 for +3.3V, pin J4-36 for Return) Copper jumper E35 must be open for any of these configurations. The pin headers supply voltage directly to the S1JA MCU, the S124 J-Link MCU, and other on-board circuitry. Use caution to ensure that any voltage connected in this manner meets the power requirements for the active features.
The actual current consumed by the MCU can vary from less than 1 mA to nearly 40 mA. Refer to the S1JA User’s Manual for more information on the electrical characteristics of the MCU.
Page 16
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Once the shorting traces have been removed, there are several options to measure current: • Pins can be installed that allow connection of a precision multi-meter or bench meter, or leaded current shunt to allow oscilloscope or data logger connection.
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) 5.4 Connectivity and Settings Throughout this section, feature configuration using copper jumpers is described. See section 3.1.1, Copper Jumpers for information on using copper jumpers. 5.4.1 Device USB The DEVICE USB Micro-B connection jack connects the Main MCU to an external USB Host, FS capable, allowing communications for testing and use of the Main MCU firmware.
4.4.2, Debug USB. 5.4.4 LEDs Two LEDs are provided on the TB-S1JA Target Board. Target Board U1 is the Main MCU, and directly controls LED1. See Figure 6 for LED1 location, Figure 9 for LED2 location, Figure 13 for LED1 circuit, and Figure 8 for LED2 circuit.
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) The behavior of the LEDs is described in the following table. Table 5. Target Board LED Functions Designator Color Function MCU control port MCU pin LED1 User LED U1 P205 U1-23 LED2...
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Figure 17. Reset Switch Circuit Figure 18. Reset Switch (S2) on Target Board 5.4.6 PMOD A A 12-pin PMOD type 2A connector is provided at PMOD A. The interface is powered for 3.3 V modules only. The Main MCU acts as the SPI master, and the connected module acts as an SPI slave device.
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) 5.4.7 PMOD B A 6-pin PMOD type 4 connector is provided at PMOD B. The interface is powered for 3.3 V modules only. The Main MCU acts as the UART DCE, and the connected module acts as the UART DTE.
Target Boards for a particular Synergy MCU Group (for example, S1/S3/S5/S7) and, where possible, across all Synergy Target Boards. On TB-S1JA, 40 pins of the pin headers are set aside for fixed function assignment. These pins are odd- numbered pins of J1 and even-numbered pins of J2.
Page 24
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) There are several pins in the headers that are Secondary Fixed Function Pins. These Secondary Fixed Function Pins share common pin assignments with other Target Boards that have Main MCUs with the same functionality.
DAC output quality. 5.6.2 On-Board Clock Crystals TB-S1JA includes two precision crystal clock sources. A precision 12.000 MHz crystal is installed at location X1, and a precision 32.768 kHz crystal is installed at location X2. These crystal clock sources are connected to the Main MCU by default.
Figure 25. User Potentiometer Circuit Figure 26. User Potentiometer on Target Board (Top) 5.6.4 Boot Configuration The BOOT CONFIG jumper, J8, is used to configure the operating mode of the S1JA MCU at boot. Table 15. Boot Configuration Boot Configuration...
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) 5.6.5 Miscellaneous Signals 5.6.5.1 AVCC0/AVSS0 and AVCC1/AVSS1 By default, AVCC0 and AVCC1 are connected to +3V3MCU, and AVSS0 and AVSS1 are connected to the system ground. To disconnect the reference voltage from AVCC0 and AVSS0, copper jumpers E10 and E11 must be open.
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) 6. Certifications The TB-S1JA meets the following certifications/standards. See the beginning of this User’s Manual for the disclaimer and precautions. 6.1 EMC/EMI Standards • FCC Notice (Class A) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 33
Renesas Synergy™ Platform Target Board Kit S1JA (TB-S1JA) Website and Support Visit the following URLs to learn about key elements of the Synergy Platform, download components and related documentation, and get support. TB-S1JA Resources renesas.com/synergy/tb-s1ja Synergy Software renesas.com/synergy/software Synergy Software Package renesas.com/synergy/ssp...
Need help?
Do you have a question about the S1JA and is the answer not in the manual?