Yamaha SRCP User Manual page 66

Single-axis robot controller
Hide thumbs Also See for SRCP:
Table of Contents

Advertisement

5-2 Parameter Description
5
8
5-
PRM24: Teaching count data (TPB entry)
This is entered in the TPB and cannot be used.
Default value: 0
PRM25: Not used
Default value: 0
PRM26: Teaching movement data
This parameter is used during movement with a communication command @X+ or @XINC.
This is also used for point teaching playback.
Input range:
1 to 100 (%)
Default value: 100
PRM27: Teaching movement data 1 (for TPB)
This is entered in the TPB and cannot be used.
Input range:
1 to 100 (%)
Default value: 100
* The TPB writes the contents of PRM27 into PRM26 when connected to the controller.
PRM28: Teaching movement data 2 (for TPB)
This is entered in the TPB and cannot be used.
Input range:
1 to 100 (%)
Default value: 50
PRM29: Teaching movement data 3 (for TPB)
This is entered in the TPB and cannot be used.
Input range:
1 to 100 (%)
Default value: 10
PRM30: Maximum program speed
The speed data defined by the MOVA, MOVI and MOVM statements in a program is
multiplied by this parameter value to determine the maximum speed at which the robot
actually moves. This is used to lower the speed of the overall program. When the TPB is
used, any speed changes in the AUTO and STEP modes will also change this parameter
value.
Max. speed (%) = PRM30 × speed operand (%) of movement command / 100
Input range:
1 to 100 (%)
Default value: 100
PRM31: Mechanical lock detection level
This parameter sets the sensitivity to detect mechanical locking caused by collision of the
robot with an object. The upper limit of this parameter is 254. The sensitivity becomes
lower as the parameter value increases. Leave this parameter set to 255 when you want to
disable this function.
Input range:
1 to 255 (.01 sec.)
Default value: 255 (This function is disabled.)

Advertisement

Table of Contents
loading

Table of Contents