Utilities - Yamaha SRCP User Manual

Single-axis robot controller
Hide thumbs Also See for SRCP:
Table of Contents

Advertisement

11-5-3 Utilities

(1-1) @INIT PGM
Initializes all program data.
Transmission example
Response example
(1-2) @INIT PNT
Initializes all point data.
Transmission example
Response example
(1-3) @INIT PRM <robot number>
Initializes the parameter data to match the specified robot.
For robot numbers, refer to "15-1-2 Robot number list".
Transmission example
Response example
(1-4) @INIT CLOCK
Initializes the timer to 0, which is used to measure the total operation time of the SRCP controller.
The alarm history and error history are also initialized at this point.
Transmission example
Response example
(1-5) @INIT ALM
Initializes the alarm history.
Transmission example
Response example
(1-6) @INIT ERR
Initializes the error history.
Transmission example
Response example
11-5 Communication Command Description
: @INIT PGM c/r l/f
: OK c/r l/f
: @INIT PNT c/r l/f
: OK c/r l/f
: @INIT PRM 516 c/r l/f ................ Parameter data is initialized to
: OK c/r l/f
: @INIT CLOCK c/r l/f
: OK c/r l/f
: @INIT ALM c/r l/f
: OK c/r l/f
: @INIT ERR c/r l/f
: OK c/r l/f
match the model MR16T
robot.
29
11-
11