R&S Tsma6 Automatically Switches Off After Power On - R&S TSMA6 Series User Manual

Autonomous mobile network scanner
Hide thumbs Also See for TSMA6 Series:
Table of Contents

Advertisement

®
R&S
TSMA6
Table 8-2: Software license key information
Label
Option Type
Option Material No.
Option key
Privilege
Time Stamp
License Count
Activation Type
Valid From
Valid To
Time to Expiration
Option Index
Format ID
8.4 R&S TSMA6 Automatically Switches Off After Power
On
1. Check if there is a battery pack unit connected.
2. Check the state of charge of the batteries.
3. Perform one of the following actions.
a) Replace the batteries with fully charged ones and try again.
b) Charge the batteries in an external charger and retry later.
c) Connect DC supply to the R&S TSMA6 battery pack unit and charge the batter-
4. Connect DC supply to the R&S TSMA6 battery pack unit and check in the web GUI
the "Shutdown Settings".
Navigate to "Configuration" > "System" > "Power" and check the state of "Auto
Power Off".
User Manual 4900.8057.02 ─ 06
R&S TSMA6 Automatically Switches Off After Power On
Description
Band or technology option name
Order number of the option
Software license key number
Usage type (customer, services, demo)
Time the software license key was installed
Number of times the (band upgrade) option is installed
Activation can be permanent or temporary
Start of validity for temporary license
End of validity for temporary license
Time left until license expires
for internal use only
for internal use only
If yes, continue with
step
If no, contact R&S support.
If the charging state is > 20% (charging indicator displays one loading bar),
continue with
step
4.
If the charging state is < 20%, an auto power off of the device is performed due
to insufficient remaining battery charge. Continue with
ies inside the bay. Keep the R&S TSMA6 switched off.
If enabled, check the shutdown delay.
2.
Troubleshooting
step 3
98