Configuration; Country / Normative - Ingeteam Ingecon Sun Lite Series Installation Manual

Table of Contents

Advertisement

La copia, circulación o uso de este documento o de su contenido requiere un permiso por escrito. Su in-
9.5

Configuration

cumplimiento será denunciado por daños y perjuicios. Todos los derechos están reservados, incluyendo
Enables verification of certain parameters for which the inverter has been configured. Access restricted to installer.
aquellos que resulten de derechos de patentes o registro del diseño.
on the CONFIGURATION option in the MAIN MENU. Giving access to the following screen:
Press
OK
La correspondencia del contenido del documento con el hardware ha sido comprobada. Sin embargo,
12:00
pueden existir discrepancias. No se asume ninguna responsabilidad por la concordancia total. La infor-
MAIN MENU
mación que contiene este documento es revisada regularmente y es posible que se produzcan cambios
en siguientes ediciones.
Monitoring
Configuration
Language
El presente documento es susceptible de ser cambiado.
Change date
Do not change any of these parameters if you are not the installer and you are not completely
sure. INGETEAM ENERGY S.A. accepts no liability for damage to the unit or the installation due to
configuration changes.
The copy, distribution or use of this document or of its content requires written authorisation. Any
breach thereof will be reported for damages. All rights reserved including those of patent rights or
The following passwords are necessary for some configuration changes: PASSSWORD, PASSSWORD 2, PASSSWORD 3.
design registration.
Given that configuration changes occur in extraordinary installation situations, the passwords are not supplied with the unit, but
rather need to be requested from INGETEAM ENERGY S.A.'s Commercial Department.
The menu will display only the configurations corresponding to the device hardware.
The conformity of the document content with the hardware described has been checked. However,
discrepancies may exist. Liability will not be assumed for total concordance. The information contained
The various available configuration changes are described below.
in this document is regularly revised and it is possible that there may be changes in subsequent

9.5.1 Country / Normative

editions.Other functions may be available which are not covered by this document.
on the COUNTRY / NORMATIVE option from the CONFIGURATION submenu.
Press
OK
This document may be changed.
12:00
CONFIGURATION
COUNTRY / NORMATIVE
GRID VOLTAGE
GROUNDING
OTHER ADJUSTMENTS
In order to make a change to COUNTRY / NORMATIVE, first press the
them both pressed for 4 seconds. A list of COUNTRY / NORMATIVE will appear on the screen.
The ">" sign shows the current selection. Select the COUNTRY / NORMATIVE you wish to change using the
and
key, then press
The following screen will be shown. Press
12:00
COUNTRY / NORMATIVE
DANMARK
ESPAÑA
ENGLAND
>DEUTSCHLAND
ITALIA
Page 48
Page 2
48
12/04/10
12/04/10
.
OK
to confirm.
OK
12/04/10
12:00
CONFIGURATION
COUNTRY / NORMATIVE
GRID VOLTAGE
GROUNDING
OTHER ADJUSTMENTS
The following screen will appear:
12:00
COUNTRY / NORMATIVE
Country
ESPAÑA
Normative
RD1663
Code 1
31F0
key, followed by
12:00
COUNTRY / NORMATIVE
ESPAÑA
RD1663 >>>
>>>DEUTSCHLAND
CONTINUE?
Confirm (OK)
Cancel (ESC)
Manual de instalación
Installation Manual
INGECON® SUN LITE
INGECON® SUN LITE
AAY2000IKH01
AAY2000IKI01
12/04/10
12/04/10
, and then keep
ESC
12/04/10
VDE0126-1-1
AAY2000IKH01
AAY2000IKI01
Rev. _B
Rev. _B
Fecha: Marzo 2011
Date: March 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents