4.3.1 Inspection tasks

aquellos que resulten de derechos de patentes o registro del diseño.
May involve opening the housing for visual inspection tasks.

4.3.2 Control tasks

La correspondencia del contenido del documento con el hardware ha sido comprobada. Sin embargo,
Tasks to load software from the communications connector.
pueden existir discrepancias. No se asume ninguna responsabilidad por la concordancia total. La infor-
mación que contiene este documento es revisada regularmente y es posible que se produzcan cambios

4.3.3 Handling tasks

en siguientes ediciones.
Tasks for the mounting and/or replacement of parts (fuses, switchgear in general, etc), tasks for disconnecting
and reconnecting voltage, connecting the inverters to equipment and connecting communications cabling to the
El presente documento es susceptible de ser cambiado.
equipment. All those tasks which are neither Inspection or Control will be considered to be Handling.

4.4 General points

This section defines the preventive measures to take to carry out all types of tasks on the unit, working safely and
controlling risks which cannot be avoided.
Protection against direct contact is by means of the housing, which has IP 65 protection class.
The copy, distribution or use of this document or of its content requires written authorisation. Any
The unit has been tested according to the applicable regulations to comply with the safety requirements, the
breach thereof will be reported for damages. All rights reserved including those of patent rights or
values for insulation distances and leakage paths for the voltages used.
design registration.
The tools and/or equipment used in handling tasks must have double reinforced insulation (class II).
The conformity of the document content with the hardware described has been checked. However,

4.4.1 General risks existing and preventive measures

discrepancies may exist. Liability will not be assumed for total concordance. The information contained
in this document is regularly revised and it is possible that there may be changes in subsequent
- Impact against immovable objects:
editions.Other functions may be available which are not covered by this document.
- Inform workers of the risk
- Adequate lighting
This document may be changed.
- Work with care
- Keep sufficient distance to prevent contact with the part causing the risk (control rod in the isolating switch
door)
- Knocks, punctures and cuts from objects and/or tools:
- Keep the lid closed if not working inside
- Adequate lighting
- Order and cleanliness
- Mandatory use of hard hat, safety footwear and gloves when necessary
- Flying particles (fan):
- Recommended use of anti-impact glasses when accessing the fan inlet and outlet zones.
- Electrical risk
- Comply with that laid down in the PPE section and in the general safety standards
- Inform the worker of the risk
- Comply with that laid down in the legislation applicable to the installation in which the unit is lo-
cated, both that for the type of installation and the country where it is located itself

4.4.2 Additional risks and measures in handling tasks

- Thermal Contact
- Inform workers of the risk
- Recommended use of gloves
- Disconnect the power and wait 10 minutes for the hot parts inside the unit (internal radiator) to cool.