The following drawings show the plate dimensions.
cumplimiento será denunciado por daños y perjuicios. Todos los derechos están reservados, incluyendo
200
80
aquellos que resulten de derechos de patentes o registro del diseño.
La correspondencia del contenido del documento con el hardware ha sido comprobada. Sin embargo,
pueden existir discrepancias. No se asume ninguna responsabilidad por la concordancia total. La infor-
mación que contiene este documento es revisada regularmente y es posible que se produzcan cambios
en siguientes ediciones.
El presente documento es susceptible de ser cambiado.
The copy, distribution or use of this document or of its content requires written authorisation. Any
breach thereof will be reported for damages. All rights reserved including those of patent rights or
design registration.
The conformity of the document content with the hardware described has been checked. However,
discrepancies may exist. Liability will not be assumed for total concordance. The information contained
in this document is regularly revised and it is possible that there may be changes in subsequent
editions.Other functions may be available which are not covered by this document.
This document may be changed.
Units with transformer:
The top attachment plate for the unit supports the weight.
The bottom point fixes the transformer to the wall and prevents vibrations.
Follow the steps below to fix the transformer to the wall:
Mark the attachment points for the plate on the wall.
Drill holes in the wall with a bit recommended for the screws to be used to secure the plate to the wall later.
Fix the plate using wall plugs and stainless steel screws to prevent corrosion.
The use of the appropriate screws (minimum external diameter 6 mm), washers and wall plugs (minimum external
diameter 18 mm) is recommended to secure the plate.
Suspend the transformer from the plate. This operation must be carried out between two people.
Screw on the bottom attachment.
Check that the transformer is secured well.
Follow the steps below to secure the inverter to the transformer:
Page 2
Page 28
28
80
Manual de instalación
Installation Manual
INGECON® SUN LITE
INGECON® SUN LITE
AAY2000IKH01
AAY2000IKI01
200 mm
324 mm
To be
fixed to
the wall
80 mm
AAY2000IKH01
AAY2000IKI01
Rev. _B
Rev. _B
Fecha: Marzo 2011
Date: March 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents