10 Communications
10.6.3. First Test
If the Periodic Test Interval is programmed as 001-254 hours, you must also program the time that the first Periodic
Test is sent.
To program the First Test Time:
1.
From the Programming menu, select Communications, Comm. Options, First Test [95403].
2.
Enter a time (HH:MM), then press
10.6.4. Auto Interval
The Auto Interval option determines the frequency of automatically calculated periodic test messages.
To program the Auto Interval:
1.
From the Programming menu, select Communications, Comm. Options, Auto Interval [95404].
2.
Select Daily, Weekly or Monthly.
10.6.5. Call Timeout
The Call Timeout is the amount of time the system waits for the first acknowledgement (ACK1) from the central
station when reporting using the PSTN. If ACK1 is not received during this time, the system regards the call as a
failed dialing attempt.
To program the Call Timeout:
1.
From the Programming menu, select Communications, Comm. Options, Call Timeout [95405].
2.
Enter a time (001-255 seconds), then press
10.6.6. ACK. Timeout
The ACK Timeout is the amount of time the system waits for the second acknowledgement (ACK2) from the central
station when reporting using the PSTN. If ACK2 is not received during this time, the system regards the call as a failed
dialing attempt.
To program the ACK Timeout:
1.
From the Programming menu, select Communications, Comm. Options, ACK Timeout [95406].
2.
Enter a time (001-255 seconds), then press
10.6.7. PSTN Country
In order to meet the requirements of local telecommunications authorities, default telephone line parameters have been
chosen for a number of different countries.
To program the PSTN Country:
1.
From the Programming menu, select Communications, Comm. Options, PSTN Country [95407].
2.
Select your country from the options available.
Note:
Electronics Line 3000 offers custom telephone line parameter settings for countries that do not appear
in the list of pre-defined options. If your country does not appear among the available options, select
the option Custom Settings.
10.6.8. Dial Tone Wait
This option determines whether the system dials only when the dial tone is present or if the dialing is initiated
regardless of the dial tone.
To program the Dial Tone Wait option:
1.
From the Programming menu, select Communications, Comm. Options, Dial Tone Wait [95408].
2.
Select Enabled or Disabled.
10.6.9. RDM Period
Remote Diagnostics and Maintenance (RDM) session is a feature that is designed to enable automated maintenance of
installed Control Systems. During a maintenance session, the Control System automatically dials the RP Callback
number and connects to the RDM server. The time interval between maintenance sessions is called the RDM period.
To program the RDM period:
1.
From the Programming menu, select Communications, Comm. Options, RDM Period [95409].
2.
Enter the required RDM period (001-255 days or 000 to disable RDM communication).