9.14. Installer Access

The Installer Access option determines if the Installer code can access the system at all times or only after the Master
code provides authorization with the Enable Programming command – see p.36, 4.8.12 Enable Programming.
To program the Installer Access option:
1.
From the Programming menu, select System Options, Instal. Access [9414].
2.
Select Always or User Initiated.

9.15. Auto Log View (for future use)

Auto Log View is a future option that is not available in the current firmware. The default setting for this option is
disabled. Electronics Line 3000 recommend that you do not change this setting.

9.16. Daylight Savings

Using the Daylight Savings option, the system is able to automatically adjust its clock twice a year according to the
national adjustment to Daylight Saving Time.
Two options are available:
Europe – the clock is adjusted forward 1hr on the last Sunday in March at 1am, the clock is adjusted
back 1hr on the last Sunday in October at 1am.
USA– the clock is adjusted forward 1hr on the second Sunday in March at 2am, the clock is adjusted
back 1hr on the first Sunday of November at 2am.
To program the Daylight Savings option:
1.
From the Programming menu, select System Options, Daylight Savings [9416].
2.
Select Europe, USA or Disabled.

9.17. Standard Type

By choosing one of the existing security standards you can change the Control System behavior accordingly.
To set the standard type:
1.
From the Programming menu, select System Options, Standard Type [9417].
2.
Select Regular, Skafor, or EN-50131.
Settings the Standard type to EN-50131 changes some of the Control System settings as described below.
9.17.1. Arm Prevention
The system can not be armed in the following cases:
Media Loss, Supervision Loss, or Device Trouble condition in all Active Communication
GPRS and/or GSM, and/or PSTN
Trouble condition (Transmitter Out of Synch, Supervision Loss, or Zone Trouble) from any Zone,
including Fire, Gas, Flood, and Environmental;
Entry/Exit Trouble – see p. 63, 9.18 Entry/Exit Trouble.
System not ready is displayed on the Control System's LCD.
In an attempt to remotely arm the system the remote arming device is notified as follows:
When arming by SMS – an SMS message "Command refused" is sent to the cellular phone;
When arming by DTMF – a negative error tone is sounded;
When arming from WUApp – System not Ready message is displayed.
1
Active communication module is a module used for events reporting.
2
If there is only one communication module (GPRS, PSTN, or GSM), any communication trouble prevents the Control System from
arming.