4.2.3. Inserting float-type Variables into a Message

iKAN display devices provide Modbus registers for 64 float variables, allowing the Host PC or a
PLC to read or write data via the Modbus TCP/ RTU protocol. These values can also be inserted
into a message. If these inserted values are modified via a remote Host or a PLC, the value will be
automatically refreshed when it is displayed on the iKAN series device.
The format for using a variable in a message is a 5-byte string as follows:
1
Delimiter
Variable Type
Character
f: Float variable (-3.4E+38 ~
%
+3.4E+38)
A maximum of 64 float variables can be stored on the iKAN series device, and are accessed using
Modbus register addresses 40000 to 40063.
Modbus Address
Decimal
Hex.
40128
0080
:
:
40255
00FF
2
Length
64
Float-type variables
Modbus Address:
3-digit decimal number
Description
3 to 5
X
X
Value Range
3.4E+38 ~ +3.4E
+38
X
Attribute
R/W