Resolver Without Encoder Data Memory - Bosch Rexroth IndraDrive CSB02 Project Planning Manual

Control sections
Table of Contents

Advertisement

90/143
Bosch Rexroth AG
Technical data - functions

Resolver without encoder data memory

Connection diagram
Power supply
Cable length
Specific technical features
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
See the connection diagram for how to connect the encoder system.
1)
Line cross section ≥ 0.5 mm²; observe allowed encoder cable
length
2)
Line cross section ≥ 0.14 mm²
Fig. 8-12:
EC connection diagram with resolver encoder system
The EC interface supplies the resolver encoder system with a carrier voltage
amplitude of 11 V
.
pp
Technical specification of the power supply: See
supply" on page 92
Observe that the resolver encoder used must be suited for the
voltage available at the EC interface as the encoder supply volt‐
age.
75 m at most
The encoder evaluation has been sized for resolvers with a transfer ratio of
0.5.
Resolvers are not supported if an optional "Safe Motion" safety technology is
available at the same time.
DOK-INDRV*-CXX02******-PR03-EN-P
chapter "Resolver power

Advertisement