Front View With Connection Points - Bosch Rexroth IndraDrive CSB02 Project Planning Manual

Control sections
Table of Contents

Advertisement

38/143
Bosch Rexroth AG
Rexroth IndraDrive control sections
5.5.3

Front view with connection points

Front view
(example)
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
2)
Only if interface 2 = PB or CN
3)
Only if interface 2 = PB, CN or EC
Tab. 5-10:
CSB02.5 type code
The figure illustrates the basic structure of the type code. Our
sales representative will help you with the current status of availa‐
ble versions.
Connection
Stranded
point
wire
[mm²]
X4
0.25–0.5
X8*
0.25–0.5
X10*
0.25–0.5
X24 P2,
X25 P1
X30*
0.25–0.5
X31
0.75–1.5
X32
0.75–1.5
X33
0.75–1.5
0.75–1.5
X35
1)
0.75–1.5
X37*
1)
0.75–1.5
X38*
1)
X41*
0.75–1.5
X42 / X43*
X48*
0.75–1.5
X49*
0.75–1.5
X61*
0.25–0.5
H1
1)
CSB02.xB only
*
Optional connection point; the optional connection points are
marked with gray background color in the exemplary figure
Tab. 5-11:
CSB02 connection points
DOK-INDRV*-CXX02******-PR03-EN-P
AWG
-
Encoder evaluation EC
-
Encoder evaluation EC
Encoder emulation EM
-
Encoder evaluation EC
Encoder emulation EM
-
-
Multi-Ethernet communication ET
-
PROFIBUS communication PB
20–14
Digital inputs/outputs
20–14
20–14
Voltage input (24V, 0V)
20–14
Digital inputs/outputs; analog inputs
(current/voltage); analog outputs (volt‐
20–14
Digital inputs/outputs
20–14
Analog inputs/outputs
20–14
Safety technology S4, S5, SB
(With SB: X41, X42, X43 not availa‐
-
-
ble; LEDs available)
20–14
(Only available in conjunction with
safety technology S4, S5, SB)
20–14
Safety technology L3
-
CANopen communication CN
-
-
Interface for control panel
Description
Probe input
Analog inputs
Bb relay
age)
Safety technology

Advertisement

Table of Contents
loading

Table of Contents