Csb02.5 Type Code - Bosch Rexroth IndraDrive CSB02 Project Planning Manual

Control sections
Table of Contents

Advertisement

DOK-INDRV*-CXX02******-PR03-EN-P
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
5.5.2

CSB02.5 type code

Short type designation 1 2 3 4 5 6 7 8 9
Example:
C S B 0 2 . 5 B - E T - E C - P B - L 3 - E C - N N - F W
Product:
CSB = Single-axis control section BASIC
Series:
02 = 02
Design:
5 = For Hxx05
Interface equipment:
B = Extended scope
Communication:
ET = Multi-Ethernet
Interface 1:
EC = Multi-encoder interface
Interface 2:
NN = Not equipped
PB = PROFIBUS
CN = CANopen
EC = Multi-encoder interface
EM = Encoder emulation
Interface 3 (safety technology)
NN = Not equipped
L3 = STO (Safe Torque Off)
S4 = Safe Motion
S5 = Safe Motion
SB = Safe Motion Bus
Interface 4:
NN = Not equipped
EC = Multi-encoder interface
EM = Encoder emulation
DA = Digital/analog I/O extension
Other design:
NN = None
Firmware:
FW = Firmware must be ordered as a separate subposition
NW = Without control panel, without firmware
1
0 1 2 3 4 5 6 7 8 9
③ ④
:
1)
2)
3)
1)
The L3, S4, S5 and SB interfaces guarantee both the function
and the certification
Bosch Rexroth AG
Rexroth IndraDrive control sections
2
0 1 2 3 4 5 6 7 8 9
37/143