The safety alert symbol (a triangle with an ex-
clamation point), which precedes the signal
words danger, warning and caution is used to
alert the reader to personal injury hazards.
______________________________________
In case of non-compliance with this safety in-
struction, death or serious injury will occur.
______________________________________
______________________________________
In case of non-compliance with this safety in-
struction, death or serious injury can occur.
______________________________________
______________________________________
In case of non-compliance with this safety in-
struction, minor or moderate injury could oc-
cur.
______________________________________
______________________________________
In case of non-compliance with this safety in-
struction, property damage could occur.
______________________________________
4

Intended Use

The system housing is for indoor use only, and
may only be used with parts indicated in this
document. Not explicitly mentioned parts may
not be installed or connected. This also applies
to cables. Usage is only allowed in explicitly
indicated configurations and combinations of
parts and with the specified software and
firmware.
Do not install and use this system housing
before you have read all relevant documents.
You must read the safety instructions and all
other directions for use before you start any
work or activity with this system housing.
The system housing has no certified func-
tional safety on board. This means that all pre-
cautions for a safe operation must be ensured
by external components.
5
Accessories, Spare Parts and Wear
Parts
The following accessories are available for this
system housing.
October 21, 2016
Typecode
NYA04.1-FAN-1DRV-
NY4922/00
NYA04.1-STRAIN-RELIEF-
5PCS-4110-NY4901
NYA04.1-STRAIN-RELIEF-
41XX-NY4901/10
The system housing does not contain any re-
placeable or wear parts. In case of failure, the
entire system housing must be replaced.
6

Ambient Conditions

Maximum environ-
ment temperature
Relative Humidity
Mechanical Strength
Pollution degree
Overvoltage category
Maximum altitude
Free air flow in vertical direction is required
above and below the system housing for a dis-
tance of minimal 10 cm for forced cooled sys-
tems and 20 cm for convection cooled systems.
If convection cooling is used (instead of
forced cooling) the system housing must be in-
stalled vertical to ensure sufficient free air flow
through the ventilation holes. In particular,
bend cables away from the ventilation holes as
near to the connectors as possible.
7

Technical Data

Requirements on Mains Circuits.
• Mains Circuits of overvoltage category II
up to 300 V AC rms.
7.1 Power supply
The power supply specifications for the system
housing are the following.
System housing power supply
Nominal voltage
Maximum supply current
Page 3 of 10
Material
Description
number
R911328062
Fan unit - 1 drive slot
R911322873
Strain relief for
NYM04.1-MCU-
NNNN-NY4110
R911172941
Strain relief for
NYM04.1-MCU-
NNNN-NY4110,
NYM04.1-MCU-
FCAT-NY4111
Operating
Storage and transport
+5 ... +55 °C
-40 °C ... +85 °C
10 % ... 90 %
5 % ... 95 %
(non-condensing)
(non-condensing)
Vibration:
Shock:
IEC 60068-2-6:2007
IEC 60068-2-27:2008
Vibration, broadband:
IEC 60068-2-64:2008
2
2
II
4000 m
Voltage and current
24V DC ± 5 %
3A
Inrush current 6A for 10 ms
R911336853-07_BAL_DOC