Ac Brushless Linear Drive Configuration (As3005); Figure 2-12. As3005 Brushless Linear Drive Module - Aerotech DR500 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

Set Up

2.2.8. AC Brushless Linear Drive Configuration (AS3005)

To configure a slot in the DR500 for an AC brushless linear drive module (Figure 2-12),
proceed with the following steps:
WARNING
To prevent another drive type from being inadvertently inserted into a slot configured for
another type drive module, the mating drive connector on the motherboard should have a
key (Aerotech part number EAM857 otherwise Schroff #21101-252) inserted into both
the A and E slot. Refer to Figure 2-3. Electrical specifications and test points are listed in
Table 2-18 and Table 2-19, respectively.
2-26
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DR500 Operation and Technical Manual
Set jumpers and drive key according to AS3005 Brushless Drive
Configuration Table 2-6.
To minimize the risk of electrical shock and bodily injury, ensure that all electrical
power switches are in the off position and disconnect main power for 1 minute before
inserting/removing drive modules or changing jumper configurations.
If the drive is not an AS3005 AC brushless drive, refer to the previous section.
Configure the appropriate bus power supply for bi-polar operation following the
Guidelines in Section 2.2.2., then, set BWx0 to position 1-4.
Figure 2-12.
Aerotech, Inc.
AS3005 Brushless Linear Drive Module
Version 16