Electrical Specifications; Table 3-15. Electrical Specifications - Aerotech DR500 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR500 Operation and Technical Manual
3.4.

Electrical Specifications

Aerotech configures each DR500 to fit the user's particular power requirements. The
possible input voltages are 115 VAC, 230 VAC, 100 VAC, and 208 VAC (refer to
Table 3-15). Each DR500 systems power specifications can be found on the power
specification tag located on the rear of the DR500 chassis (see following example).
Example:
115V~ 50/60Hz 5A
Hazardous voltage may be present.
Table 3-15.
Electrical Specifications
VAC IN
# of
RMS
Axis
2
115VAC
2
±10%
4
230VAC
2
±10%
4
100VAC
2
±10%
4
208VAC
2
±10%
4
Line Frequency:
Installation category: Overvoltage Category II
Equipment class:
Version 1.6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Max. AC
Bus Voltage
Line Input
5A
40,60,80
10A
160
10A
(40,60,80,160)
5A
(40,60,80,160)
5A
(40,60,80,160)
5A
(40,60,80,160)
10A
(40,60,80,160)
5A
(40,60,80,160)
5A
(40,60,80,160)
50 Hz to 60 Hz
Class I (equipment with basic insulation/grounded)
Aerotech, Inc.
Technical Details
Max. Watts Out
350
1000
2000
350
700
350
700
350
700
WARNING
3-19

Advertisement

Table of Contents