Internal System Wiring; Table 2-18. As3005 Series Electrical Specifications; Table 2-19. As3005 Series Test Points - Aerotech DR500 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR500 Operation and Technical Manual
Table 2-18.
AS3005 Series Electrical Specifications
Peak Current Output (2 sec)
Continuous Output Current
Output Fuse, F1 (3 AG, slow blow)
Peak Output Voltage
Gain (continuous output)
Shutdown Input
Minimum Load
Operating Temperature
Storage Temperature
Weight
* Load dependent, consult factory.
Table 2-19.
AS3005 Series Test Points
Test Point
TP5
TP8
TP10
TP12
TP6
TP9
TP11
TP7
DS1
TP4
TP3
TP2
P2
P3
P4

2.2.9. Internal System Wiring

The DR500 wiring varies depending upon the desired AC input voltage, the number of
axes, and the desired DC bus voltage required for the drive modules. A system wiring
drawing is provided with the documentation package for all DR500 systems.
Version 1.6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Units
Amps
Amps
Amps
Volts
Power Amplifier
Amps/Volt
ohms
°C
°C
kg (lb)
Signal
Phase C Current Feedback
Phase B Current Feedback
Phase A Current Feedback
Torque Command (Phase A)
Phase C Current Command
Phase B Current Command
Phase A Current Command
Torque Command (Phase B)
L.E.D. Drive Enable
Common
-12V
+12V
Phase B Offset Adjust
Phase A Offset Adjust
Phase C Offset Adjust
Aerotech, Inc.
AS3005
5
*
*
30
.5
Removes Input Command
4
0 to 50
-30 to 85
0.5 (1)
Set Up
2-27

Advertisement