Table 2-2.
Drive Interface Board Jumper Selections (Continued)
Configuration
Install:
Remove: BW5
Bus Power Supply #1
Install:
Remove: BW5, BW54, BW55
Add:
Install:
Remove: BW8
Bus Power Supply #2
Install:
Remove: BW8, BW56, BW57
Add:
30-40, 30-80, 30-160, 30-160LT, 40-30, 40-80, 40-160, 40-160LT, 80-30, 80-40, 80-160,
80-160LT, 160-30, 160-40, 160-80, 160-160LT, 160LT-30, 160LT-40, 160LT-80,
160LT-160
IN:
Bus Voltages
Different:
OUT: BW2, BW24, BW52
Bus Separation
2-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
DR500 Operation and Technical Manual
Standard
Unipolar (0-X, 40-X, 80-X, 160-X)
BW4, BW6, BW54, BW55
Unipolar (160LT-X)
BW4 & BW6
TR1, TR2 (CL-11, ECR130)
Unipolar (X-0, X-40, X-80, X-160)
BW7, BW9 BW56, BW57
Unipolar (X-160LT)
BW7, BW9
TR3, TR4, (CL-11, ECR130)
Split 2-2:
BW1, BW3, BW14, BW34, BW51,
BW53
Aerotech, Inc.
Jumpers
Optional
Bipolar (30-X)
Install:
BW5
(EIK00226
CONN. TAB), BW54, BW55
Remove: BW4, BW6
Bipolar (X-30)
Install:
BW8
(EIK00226
CONN. TAB), BW56, BW57
Remove: BW7, BW9
Split 1-3:
IN:
BW2, BW3, BW24, BW34, BW52,
BW53
OUT: BW1, BW14, BW51
Split 3-1:
IN:
BW1, BW2, BW14, BW24, BW51,
BW52
OUT: BW3, BW34 , BW53
Bus 1 and Bus 2 the same: 40-40, 80-80,
160-160, 160LT-160LT:
or
Bus 1 or Bus 2 is 0V: 30-0, 40-0, 80-0, 160-
0, 160LT-0, 0-30, 0-40, 0-80, 0-160, 0-
160LT:
IN:
BW1, BW2, BW3, BW14, BW24,
BW34, BW51, BW52, BW53
QUICK
QUICK
Version 16