Drc I/O Cable - Aerotech DR500 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR500 Operation and Technical Manual
R2
20K
TP1
R5
R1
R3
P1
DZ1
R4
8K
5W
.1, 10 Ohm Snubber
P2
TP2
Figure 1-5.
Shunt regulator circuit operates at a high DC bus voltage.

1.2.2. DRC I/O Cable

The DRC I/O cable serves two purposes when used with the DR500 Drive Chassis. The
primary use is for applications that use brushless motors with Hall effect sensors. In such
cases, the necessary Hall effect signals are not available through the standard OP500
cable, therefore, the DRC cable is connected between the U600/U500 and the DR500.
Different versions of the DRC I/O cable are available for (1) directly connecting the
U600/U500 and
a PB8, PB16, or PB24 interface board to allow additional
inputs/outputs; or (2), connecting the U600/U500 to the DR500 (to provide Hall effect
inputs and extra I/O) with an additional connection for an optional PB8, PB16, or PB24
I/O board.
The second purpose is to allow more than four user inputs or outputs (as in the case when
the PB8, PB16, or PB24 I/O board is used).
Figure 1-6 is an illustration of the DRC I/O cable. Refer to Figure 1-7 for illustrations of
two versions of the DRC I/O cable.
See the U600 Hardware manual, EDU154, for complete information on using the
DRC cable. Figure 1-7 is for reference only.
The DRC cable is not needed to provide Hall effect signals with the U500 PCI board.
Version 1.6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Turret Terminal
(2 Places)
TP3
1
C1
.01UF
D1
C2
.47UF
Q1
6.2K
IRF640
1N4740
Q1
SNB1
Heatsink
F1 3A
Optional Shunt BD. 690C1488 (REV -) EFN169
SHUNT500 Board
Aerotech, Inc.
Heatsink
P4
P3
Introduction