Drc I/O Cable - Aerotech DR300 Operation & Technical Manual

Drive chassis
Table of Contents

Advertisement

DR300 Operation and Technical Manual

1.2.2. DRC I/O Cable

The DRC I/O cable serves two purposes when used with the DR300 Drive Chassis. The
primary use is for applications that use brushless motors with Hall effect sensors. In such
cases, the necessary Hall effect signals are not available through the standard OP500
cable, therefore, the DRC cable is connected between the UNIDEX 600/U500 and the
DR300. Different versions of the DRC I/O cable are available for (1) directly connecting
the UNIDEX 600/U500 and a PB8, PB16, or PB24 interface board to allow additional
inputs/outputs; or (2), connecting the U600/U500 to the DR300 (to provide Hall effect
inputs and extra I/O) with an additional connection for an optional PB8, PB16, or PB24
I/O board.
The second purpose is to allow more than four user inputs or outputs (as in the case when
the PB8, PB16, or PB24 I/O board is used).
Figure 1-6 is an illustration of the DRC I/O cable. Refer to Figure 1-7 for illustrations of
two versions of the DRC I/O cable.
See the U600 Hardware manual, EDU154, for complete information on using the
DRC cable. Figure 1-6 is for reference only.
The DRC cable is not needed to provide Hall effect signals when the U500 PCI
board and the DR300 rear panel interface PCB (Rev. A & later) are used.
Version 1.5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Aerotech, Inc.
Introduction
1-5