SD42800 $SC_SPIND_ASSIGN_TAB[1] = 5
SD42800 $SC_SPIND_ASSIGN_TAB[2] = 3
SETMS (2)
...
M5
...
GET (S4)
...
RELEASE (S1)
...
M30
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
SD42800 $SC_SPIND_ASSIGN_TAB[0] = 2 defined internally by NCK.
Master spindle = address extension = 2, spindle number M3=5
The physical spindle configured with number "3" stops.
Alarm 16105, as logical spindle "4" cannot be switched.
Channel spindle "1" = physical. Spindle "5" is enabled.
2.4 Selectable spindles
Assignment of logical spindle 1 to physical
spindle 5
Assignment of logical spindle 2 to physical
spindle 3.
Caution:physical spindle 3 has now been
assigned twice. When programming logical
spindles 2 and 3, physical spindle 3 is always
addressed. In the basic machine displays, both
spindles rotate.