PI service: TRESMO
Function Reset monitoring values:
This PI service resets the monitoring values of the designated edges of the designated tools
to their setpoint (initial) values.
This only relates to tools with active monitoring.
Compare the NC-Speech Command RESETMON.
Parameterization
Signal
PIService
Unit
WVar1
WVar2
WVar3
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Type
Range of
values
ANY
PI. TRESMO
INT
1 - 10
WORD
-max ..max
WORD
0 ... max.
WORD
0 ...15
Significance
Reset monitoring values
TO area
ToolNumber
0: Applies to all tools
>0: Applies only to this tool
<0: Applies to all sister tools of the specified T No.
D number
>0: Monitoring of specified edge of specified tools is reset.
0: Monitoring of all edges of specified tools is reset.
Monitoring types
Type of monitoring to be reset.
This parameter is binary-coded.
1: Tool-life monitoring is reset.
2: Count monitoring is reset.
4: Wear monitoring is reset.
8: Sum-offset monitoring is reset.
Combinations of monitoring types can be reset by adding
the values above.
0: All active tool-monitoring functions ($TC_TP9) are reset.
Detailed description
2.12 Block descriptions