Feeds (V1); Signals To Channel (Db21 - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed Description

2.16 Feeds (V1)

2.16
Feeds (V1)
2.16.1

Signals to channel (DB21, ...)

DB21, ...
DBX0.6
Activate dry run feed
Edge evaluation: yes
Signal state 1 or
The dry run feed rate defined using the setting data:
edge change
SD42100 $SC_DRY_RUN_FEED
0 → 1
is used instead of the programmed feed (forG01, G02, G03) if the dry run feed rate is greater than
that programmed.
The dry run feed rate is effective after the reset state.
This interface signal is evaluated at NC start when the channel is in the "reset" state.
The dry run feed can be activated from the PLC or operator panel.
When selected from the operator panel front, the PLC interface signal:
DB21, ... DBX24.6 (dry run feed selected)
is set and transferred from the PLC basic program to the interface signal:
DB21, ... DBX0.6 (activate dry run feed).
When selected using the PLC, the IS "activate dry run feed" should be set from the PLC user
program.
Signal state 0 or
The programmed feed is used.
edge change
Effective after the reset state.
1 → 0
Application
Testing a workpiece program with an increased feed rate.
example(s)
Special cases,
If the signal changes to "0" within a G33 block, the programmed feed is not activated until the end of
errors, ......
the block is reached, since an NC stop was not triggered.
Corresponding to ....
DB21, ... DBX24.6 (dry run feed rate selected)
SD42100 $SC_DRY_RUN_FEED (dry run feed rate)
DB21, ...
DBB4
Feed rate override
Edge evaluation: no
130
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Basic logic functions: NC/PLC interface signals (Z1)