DB19
DBW2
Higraph first error display
Edge evaluation: no
DB19
DBW4
Higraph first error display
Edge evaluation: no
DB19
DBX6.0...7
Analog spindle 1, utilization in percent
Edge evaluation: no
DB19
DBX7.0 - DBX7.7
Analog spindle 2, utilization in percent
Edge evaluation: no
DB19
DBX8.0 - DBX8.7
Channel number of the machine control panel to HMI
Edge evaluation: no
DB19
DBX10.0
Programming area selection
Edge evaluation: no
Signal state 1 or
Program area selection active
edge change 0 → 1
Signal state 0 or
Program area selection inactive
edge change 1 → 0
DB19
DBX10.1
Alarm area selection
Edge evaluation: no
Signal state 1 or
Alarm area selection active
edge change 0 → 1
Signal state 0 or
Alarm area selection inactive
edge change 1 → 0
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
2.1 Various interface signals and functions (A2)
Detailed Description