Siemens SINUMERIK 840D sl Function Manual page 2099

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

DB21, ...
DBX318.1
Block search via program test is active
Edge evaluation: no
Signal state 1 or
During the processing of the part program block in context of block search (internal channel status:
edge change
"Program test"), up to the change of the target block in the main execution (Program status:
0 → 1
"Stopped").
Signal status 0 or
With the change of the target block in the main execution (internal channel status: "Program test" is
edge change
de-selected; Stop condition: "Search target found" is displayed).
1 → 0
Special cases,
The block search (SERUPRO) can only be activated in AUTOMATIC mode in program status
errors, ......
"Aborted".
DB21, ...
DBX319.0
REPOSMODEEDGEACKN
Edge evaluation: yes
Signal state 1 or
The interface signal detected by the NCK:
edge change
DB21, ... DBX31.4 (REPOSMODEEDGE)
0 → 1
is acknowledged with the interface signal:
DB21, ... DBX319.0 (REPOSMODEEDGEACKN)
, if level signals from:
DB21, ... DBX31.0 - DBX31.2 (REPOSMODE0-2)
and from:
DB31, ... DBX10.0 (REPOSDELAY)
are taken over in the NC.
The levels relate to the current block in the main run.
Signal state 0 or
SERUPRO-ASUP stopped automatically before the REPOS and NST DB21, ... DBX319
edge change
(REPOSMODEEDGE) does not affect SERUPRO approach.
1 → 0
Corresponds to ....
DB21, ... DBX31.4 (REPOSMODEEDGE)
DB21, ...
DBX319.1 -
Repos Path Mode Ackn 0 - 2
DBX319.3
Edge evaluation: no
Signal state 1
Using the interface signal:
DB21, ... DBX319.1 - DBX319.3 (Repos Path Mode Ackn 0-2)
with the 3 bits, one of the functions for the re-approach point RMB, RMI, RME or RMN can be
acknowledged according to the following coding to the PLC:
DB21, ... DBX319.1 - DBX319.3 = 1 → RMB: Re-approach at the start of the block
DB21, ... DBX319.1 - DBX319.3 = 2 → RMI: Re-approach at the point of interruption
DB21, ... DBX319.1 - DBX319.3 = 3 → RME: Re-approach at the end of the block
DB21, ... DBX319.1 - DBX319.3 = 4 → RMN: Re-approach at the nearest path point
Signal state 0
DB21, ... DBX319.1 - DBX319.3 = 0
→ RMNOTDEF: The ReposMode that is not re-defined is acknowledged to the PLC.
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.9 Mode group, channel, program operation, reset response (K1)
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Detailed Description
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents