The modified version of the program call starts from here.
Here the call in OB 100 is displayed.
Here the call still remaining in OB 1 is displayed.
Note
Owing to this measure, a shorter cycle time is achieved in OB 1, because the static
parameter values need not be copied in the instance DB in each OB-1 cycle.
The savings of this variant:
The cyclic copying effort of 3 integer values and 4 ""ANY" parameters with respect to the
instance DB, which results from 3 time loading of a constant in the instance data block. In
case of each "ANY" transfer, constants are loaded in the data block 4 times with subsequent
transfer.
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
CALL FB 2, DB 110 (
Req :=
NumVar :=
Addr1 :=
Line1 :
Addr2 :=
Line2 .
RD1 :=
RD2 :=
CALL FB 2, DB 110 (
Req :=
Error :=
NDR :=
State :=
FALSE,
2,
NCVAR.C1_RP_rpa0_0
W#16#1
NCVAR.C1_RP_rpa0_0
W#16#2
P#M 4.0 REAL 1,
P#M 24.0 REAL 1,
M0.0,
M1.0,
M1.1,
MW 2,
Detailed description
2.14 Programming tips with STEP 7
//Read 2 variables
263