Detailed description
2.12 Block descriptions
Call example
CALL FC 8 (
u m 20.6;
r m 20.5;
spb m001;
l DB61.dbw 12;
ow w#16#0;
JC error;
m001:
error:
r m 20.5:
196
//Tool-management transfer block
Start :=
m 20.5,
TaskIdent :=
DB61.DBB 0,
TaskIdentNo :=
DB61.DBB 1,
NewToolMag :=
DB61.DBW 2,
NewToolLoc :=
DB61.DBW 4,
OldToolMag :=
DB61.DBW 6,
OldToolLoc :=
DB61.DBW 8,
Status :=
DB61.DBW 10,
Ready :=
m 20.6,
Error :=
DB61.DBW 12);
//Start := "1 " => transfer trigger
//Current position of new tool
//Current position of old tool
//Status
//Poll ready
//Reset start
//Jumps, if everything OK
//Error information
//Evaluate error
//Jumps to troubleshooting
//Normal branch
//Troubleshooting
//Reset start