Siemens SINUMERIK 840D sl Function Manual page 1383

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

END_VAR
VAR_OUTPUT
Error :
NDR :
State :
END_VAR
VAR_IN_OUT
END_VAR
Description of formal parameters
The table below list all formal parameters of the GET function.
Signal
Req
NumVar
Addr1 to Addr8
Unit1 to Unit8
Column1 to
Column8
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Column6 :
Line6 :
Addr7 :
Unit7 :
Column7 :
Line7 :
Addr8 :
Unit8 :
Column8 :
Line8 :
RD1 :
RD2 :
RD3 :
RD4 :
RD5 :
RD6 :
RD7 :
RD8 :
Typ
Type
e
I
BOOL
I
INT
I
ANY
I
BYTE
I
WORD
WORD ;
WORD ;
ANY ;
BYTE ;
WORD ;
WORD ;
ANY ;
BYTE ;
WORD ;
WORD ;
BOOL ;
BOOL ;
WORD ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
Range of values
1 ... 8
(corresponds to use of
Addr1 to Addr8)
[DBName].[VarName]
Detailed description
2.12 Block descriptions
Remark
Job start with positive signal edge
Number of variables to be read
Variable identifiers from
NC Var selector
Area address, optional for variable
addressing
Column address, optional for variable
addressing
109