2.4.2
Application of basic program
A new CPU program (e.g., "Turnma1") must be set up in a project by means of the STEP7
software for each installation (machine).
Comment
The catalog structures of a project and the procedure for creating projects and user
programs are described in the relevant SIMATIC documentation.
Procedure
The basic-program blocks are copied using the SIMATIC Manager and File/Open/Library.
The following components must be copied from the library:
• From the block container: FCs, FBs, DBs, OBs, SFC, SFB, UDT
• Source_files (from the source container): GPOB840D
• Possibly MDECLIST, HHU_DB and others
• The symbols table (from the symbols container)
Compatibility with STEP 7
There are no dependencies between the basic program and current STEP7 versions.
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Detailed description
2.4 Starting up the PLC program
19