Loading the Factory Defaults Using DashBoard
If you need to return the RCP-ME to a known configuration, you can use DashBoard to load the factory defaults.
This defaults the RCP-ME panel configuration (Panel Config interface settings) only, and not the connection
configuration (Connection Editor).
To load the factory defaults
1.
Open the RCP-ME Panel Config interface (see "To open the RCP-ME Panel Config interface" on page 22).
2.
Select the Configuration tab.
3.
In the Configuration section, select the Load Factory Defaults check box.
4.
Send the current configuration file to the device (see "To send the current configuration to a panel" on
page 74).
Ensure that only the Home page box is selected in the Send Configuration dialog. De-select all other pages or
they will be sent to the device as well, thus changing the factory defaults.
The factory defaults are loaded.
RCP-ME User Guide (v4.0)
Managing Panel Configurations • 75