To-deassign a resource
1.
Select the destination to which the resource is attached.
2.
Press DE-ASIGN.
If the selected destination does not include a resource, one of two things will occur:
• If the panel is in MC mode, park the current destination (switch same source number to destination).
• If the panel is not in MC mode, it displays the MC MODE? message.
The ability of a panel to de-assign a resource using the de-assign button will depend on the priority assigned to
the panel and the resource in the NK-VRC virtual routing core.
Resetting Devices
To return the RCP-ME to a known operating state and configuration, perform one of the following:
• send a saved configuration to the RCP-ME (see "Saving the Current Configuration for the RCP-ME" on
page 73)
• reset the RCP-ME
• reload the factory defaults on the RCP-ME
If the RCP-ME fails to accept any configuration files that are sent to it, then you should reset the device. When you
perform a reset, the RCP-ME takes on the last-known operating state and configuration that is stored in memory. If
the RCP-ME fails to reset, then reload the factory defaults.
To reset a device
1.
Open the RCP-ME Panel Config interface (see "To open the RCP-ME Panel Config interface" on page 22).
2.
Click
.
Reboot
To reload a default configuration
1.
Open the RCP-ME Panel Config interface (see "To open the RCP-ME Panel Config interface" on page 22).
2.
Select the Configuration tab.
3.
Select the Load factory defaults check box.
4.
Click
Send Configuration
The panel will reload factory defaults.
If the RCP-ME is connected to an Ultricore control system, the default labels will be overwritten with the current
database. The button assignment will remain as per the default.