Destination and Sources

Destination and source buttons map the physical connections on the routing switcher to the RCP-ME. You can
provide labels for these physical connections using the Input Assigns and Output Assigns tabs in the Panel Config
interface for the RCP-ME.
If the RCP-ME is connected to an Ultrix router or Ultricore Central Controller, the number of inputs and outputs
are defined by the Ultrix/Ultricore set up. Changes to Ultrix/Ultricore will overwrite any manual changes made
on the remote control panel.
For More Information on...
• the options in the Output Assigns and Input Assigns tabs, refer to the section "Output/Input Assigns Tabs" on
page 89.

Specifying the Number of Outputs/Inputs

Depending on the size of the routing switchers connected, you may choose to increase or reduce the number of
output and input labels to match the size of the routing switcher if virtual routing is not used. The number can be
changed in increments of 8.
To change the number of possible inputs and outputs
1.
Open the RCP-ME Panel Config interface (see "To open the RCP-ME Panel Config interface" on page 22).
2.
Perform one of the following:
• To change the number of outputs, select the Output Assigns tab.
• To change the number of inputs, select the Input Assigns tab.
3.
Use the Number of outputs/Number of inputs box to enter or select the number of outputs/inputs to match
the requirements of your routing switcher system.
4.
Click
.
Update
5.
If you want to transfer this number of outputs/inputs to the other tab, click Copy to Input Assigns/Copy to
Output Assigns. The labels are also copied.
6.
Send the current configuration file to the device (see "To send the current configuration to a panel" on
page 74).

Assigning Output and Input Labels

Source and destination equipment is physically connected to routing switchers. This connection information must
be displayed meaningfully on the RCP-ME. This information is set up on the Input Assigns and Output Assigns
tabs.
To assign output and input labels
1.
Open the RCP-ME Panel Config interface (see "To open the RCP-ME Panel Config interface" on page 22).
2.
Perform one of the following:
• To change the label for an output, select the Output Assigns tab.
• To change the label for an input, select the Input Assigns tab.
3.
Click to highlight the text in the Label column corresponding to the output/input to which the item of
destination/source equipment is connected.
4.
Enter the name of the item of destination/source equipment.
RCP-ME User Guide (v4.0)
Destination and Sources • 29