11.4

Allocation of Device Numbers to Input Numbers

The high-speed counter numbers are allocated to the input terminals X000 to X007 as shown in the following
table. The input terminals not allocated for high-speed counters can be used as general input terminals.

11.4.1 Allocation table

U: Up-count input
R: External reset input
Counter type
1-phase 1-count
input
1-phase 2-count
input
2-phase 2-count
input
*1.
When a special auxiliary relay is driven in a program, the input terminals and their associated
functions are switched.

11.4.2 Restriction of redundant use of input numbers

The input terminals X000 to X007 can be used for high-speed counters, input interruption, pulse catch, SPD,
ZRN and DSZR instructions and general-purpose inputs. Take care not to overlap the input numbers.
D: Down-count input
S: External start input
Counter No.
X000
X001
C235
U/D
C236
U/D
C237
C238
C239
C240
C241
U/D
R
C242
C243
C244
U/D
R
C245
C246
U
D
C247
U
D
C248
*1
C248(OP)
C249
U
D
C250
C251
A
B
C252
A
B
C253
*1
C253(OP)
C254
A
B
C254(OP)*1
C255
→ For the function switching method, refer to Subsection 11.9.2.
11.4 Allocation of Device Numbers to Input Numbers
A: A-phase input
Input allocation
X002
X003
X004
X005
U/D
U/D
U/D
U/D
U/D
R
U/D
R
U/D
R
R
U
D
R
U
D
R
U
D
R
R
A
B
R
A
B
R
A
B
R
11 Use of High-speed Counters
B: B-phase input
X006
X007
S
S
S
S
S
A
B
S
163
11
12
13
14
15
16
17
18
19