Mitsubishi Electric MELSEC-F FX3G Series User Manual page 401

Hide thumbs Also See for MELSEC-F FX3G Series:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3G
User's Manual - Hardware Edition
Number and
Operation and function
name
Parallel Link
Parallel link
*1
Set M8070 when using master
M 8070
station.
Parallel link
*1
Set M8071 when using slave
M 8071
station.
Parallel link
[M]8072
ON when operating
Parallel link
[M]8073
ON when M8070 or M8071
setting is incorrect
*1.
Cleared when PLC switches from STOP to RUN.
Pulse width/Pulse period measurement function
Pulse width/Pulse period
*2
[M]8075
measurement setting flag
[X000] Pulse width/Pulse period
*2
[M]8076
measurement flag
[X001] Pulse width/Pulse period
*2
[M]8077
measurement flag
[X003] Pulse width/Pulse period
*2
[M]8078
measurement flag
[X004] Pulse width/Pulse period
*2
[M]8079
measurement flag
[X000] Pulse period measurement
*2
M 8080
mode
[X001] Pulse period measurement
*2
M 8081
mode
[X003] Pulse period measurement
*2
M 8082
mode
[X004] Pulse period measurement
*2
M 8083
mode
*2.
Supported in Ver. 1.10 or later.
Flag
[M]8090 to [M]8100 Not used
Memory Information
[M]8101
[M]8102
Not used
[M]8103
[M]8104
[M]8105
ON during writing in RUN mode
[M]8106
[M]8107
Not used
[M]8108
Output Refresh Error
[M]8109
Output refresh error
[M]8110
Not used
[M]8111
FX
-4EX-BD
3G
*3
BX0 input
[M]8112
*3
BX1 input
[M]8113
*3
BX2 input
[M]8114
*3
BX3 input
[M]8115
Appendix A-1 Special Auxiliary Relay (M8000 to M8511)
Correspond-
Number and
ing special
name
device
FX
3G
-2EYT-BD
*3
M 8116
-
*3
M 8117
[M]8118
-
[M]8119
*3.
Supported in Ver. 2.20 or later.
-
RS (FNC 80) and Computer Link [ch1]
[M]8120
-
*4
[M]8121
*4
M 8122
*4
M 8123
-
D8074 to
[M]8124
D8079
[M]8125
D8080 to
[M]8126
D8085
D8086 to
[M]8127
D8091
D8092 to
M 8128
D8097
D8074 to
D8079
M 8129
D8080 to
D8085
D8086 to
*4.
Cleared when PLC switches from RUN to STOP or RS
D8091
instruction is OFF.
D8092 to
D8097
Positioning [PLSY, PLSR instruction]
M 8145
M 8146
-
[M]8147
[M]8148
-
-
Inverter Communication Function
-
[M]8150
-
*6
[M]8151
-
*5*6
-
[M]8152
-
*5*6
[M]8153
-
[M]8154
[M]8155
D8109
-
*6
[M]8156
-
*5*6
[M]8157
*5*6
-
[M]8158
-
[M]8159
-
*5.
Cleared when PLC switches from STOP to RUN.
*6.
Supported in Ver. 1.10 or later.
-
Appendix A: Special Device List
Operation and function
BY0 output
BY1 output
Not used
Not used
RS (FNC 80) instruction:
Send wait flag
RS (FNC 80) instruction:
Send request
RS (FNC 80) instruction:
Receive complete flag
RS (FNC 80) instruction:
Carrier detection flag
Not used
Computer link [ch1]: Global ON
Computer link [ch1]:
On-demand send processing
Computer link [ch1]:
On-demand error flag
Computer link [ch1]:
On-demand Word/Byte
changeover
RS (FNC 80) instruction:
Time-out check flag
[Y000] Pulse output stop command
[Y001] Pulse output stop command
[Y000] Pulse output monitor
(BUSY/READY)
[Y001] Pulse output monitor
(BUSY/READY)
Not used
Inverter communication in
execution [ch1]
Inverter communication error [ch1]
Inverter communication error latch
[ch1]
Not used
Inverter communication in
execution [ch2]
Inverter communication error [ch2]
Inverter communication error latch
[ch2]
Not used
21
Correspond-
ing special
device
-
22
-
-
-
A
-
-
D8122
D8123
B
-
-
C
D8127
D8128
D8129
D
-
-
E
-
-
-
D8151
D8152
D8153
-
-
D8156
D8157
D8158
-
395

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents