Display And Operating Elements; Led-Display; Push-Buttons - Pepperl+Fuchs VBG-EN-K20-D Manual

As-interface/ethernet ip-gateway
Hide thumbs Also See for VBG-EN-K20-D:
Table of Contents

Advertisement

5.3

Display and operating elements

5.3.1

LED-display

There are seven light-emitting diodes on the front panel of the gateway . They
have the following function:
Power
Ser. active
Triple flash
Quadruple
flash
Quintuple
flash
On
Config err
U AS-i
AS-i active
prg enable
prj mode
5.3.2

Push-buttons

The push-buttons cause the following:
Mode/⇑›
Set/⇓
OK, ESC
Subject to reasonable modifications due to technical advances.
16
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Connections, Displays and Operating Keys
The master's power supply is sufficient.
Status of the Ethernet connection indicates as follows:
Display "Ser. active"
No valid Ethernet signal viewed
Please examine the plugs for correct seat
No MAC address assigned.
Please send the equipment back to the manufacturer!
Determines an IP address via DHCP
The gateway is OK, an IP number was assigned
Configuration error:
At least one configured slave is missing, at least one detected
slave is not projected or for at least one projected and detected
slave the actual configuration data does not match the nominal
configuration data.
This LED flashes if there is at least one periphery fault at one
AS-i slave in the AS-i network. If there are configuration errors as
well as periphery faults, only configuration error is displayed.
The AS-i circuit is sufficiently powered.
Normal operation active.
Automatic address programming enabled.
Exactly one slave is missing in protected operating mode. The
slave can be replaced by another slave of the same type with ad-
dress zero. The master addresses the new slave to the faulty ad-
dress and thus eliminates the configuration error.
The AS-i master is in configuration mode.
Switching between configuration mode and protected operating
mode and saving the current AS-i configuration as the nominal
configuration.
Selecting and assigning the address to a slave.
Changing to the advanced display mode (see <chapter 7>).