Pepperl+Fuchs VBG-EN-K20-D Manual page 118

As-interface/ethernet ip-gateway
Hide thumbs Also See for VBG-EN-K20-D:
Table of Contents

Advertisement

Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
...
Byte 12
Byte 1
Byte 2
Byte 3
Byte 4
...
Byte 12
No result because toggle bit = 0.
Set the toggle bit:
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
...
Byte 12
Byte 1
Byte 2
Byte 3
Byte 4
...
Byte 12
Subject to reasonable modifications due to technical advances.
116
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Request: SET_PCD
25
(SET_PCD)
hex
00
(T = 0, master 1, single master)
hex
04
(slave address to write to master)
hex
EF
(ID + IO to configurate)
hex
37
(xID2 + xID1 to configurate)
hex
00
hex
...
00
hex
Response
00
(or old values)
hex
00
(or old values)
hex
00
(or old values)
hex
00
(or old values)
hex
...
00
(or old values)
hex
Request: SET_PCD
0C
(SET_PCD)
hex
80
(T = 1, master 1, single master)
hex
04
(slave address to write to master)
hex
EF
(ID + IO to configurate)
hex
37
(ID + IO to configurate)
hex
00
hex
...
00
hex
Response
25
hex
80
(T = 1, result = 0)
hex
00
(or old values)
hex
00
(or old values)
hex
...
00
(or old values)
hex
AS-Interface
Command Interface
Copyright Pepperl+Fuchs, Printed in Germany