Backup Function Of Master Operation On System Switching Between Control System And Standby System - Mitsubishi Electric MELSEC Q Series Reference Manual

Q corresponding melsecnet/h network system
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
Table Of Contents
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400

Advertisement

7
APPLICATION FUNCTIONS
7.11.1 Backup function of master operation on system switching between control system
and standby system
Multiplexed remote master station (DM
Control system
Tracking cable
7 - 34
(a)
The redundant system consists of a control system (multiplexed remote
master station) and standby system (multiplexed remote sub-master
station) of the same system configuration. If a power supply error or CPU
error occurs in the control system, the Redundant system switches the
standby system to the control system to continue the operation of the
redundant system.
With the system switching, the master module mounted in the multiplexed
remote master station of the new standby system stops master operation
and the multiplexed remote sub-master station of the new control system
takes over the master operation to continue the control of remote I/O
stations.
R
Standby system
Remote I/O station (R)
Remote I/O station (R) Remote I/O station (R)
POINT
The transient transmission executed when the master operation station is switched
or returns to the system may be unsuccessfully completed. Execute the transient
transmission again if it is unsuccessfully completed.
(b)
The sub-master station always receives the cyclic transmission data
(remote I/O station to master station: X, B, and W) sent by remote I/O
stations even while the master station operates normally in order to
continue the control of the remote I/O stations smoothly when master
operation is switched.
(c)
The multiplexed remote master station and multiplexed remote sub-master
station always transfer data to each other through a tracking cable
(tracking) in order to continue the control of remote I/O stations smoothly
when master operation is switched.
POINT
When tracking the link special relay and link special register, do not transfer the link
special relays (SB0020 to SB01FF) and link special registers (SW0020 to
SW01FF) used by the system.
)
Multiplexed remote sub-master station (DSM
Standby system
MELSEC-Q
)
R
Control system (execution of master operation)
7 - 34