TROUBLESHOOTING
Error code
F820
Link parameter error
F821
Station-specific parameter error
F822
System error
F823
Parameter consistency error
F825
CPU parameter check error
F826
Parameter mismatch error
F828
No control station shift setting
F829
Pairing setting error
Network type mismatch (normal station
F82A
detected)
Network type mismatch (control station
F82B
detected)
F830
System error
F831
System error
F832
Data link startup condition error
F833
Keyword error
F834
System error
F835
System error
F836
System error
F837
Exceeded number of retries
F838
Relevant timer timeout
No link parameter
F839
(communication impossible)
F83A
SW0000 out of range error
8 - 40
Table 8.1 Error code list (Continued)
Description
Replace the network module of the normal station with the one compatible with
the MELSECNET/H Extended mode.
Change the network type of the normal station to that of the control station.
Create new network parameters and perform Write to PLC.
If the error reoccurs, the hardware of the CPU or network module is faulty.
Please consult your local Mitsubishi representative.
Review station-specific parameters.
Set common parameters
of the host station.
If no station-specific parameters are set, the hardware of the CPU or network
module is faulty.
Please consult your local Mitsubishi representative.
The hardware of the CPU or network module is faulty.
Please consult your local Mitsubishi representative.
Set common parameters
of the host station.
If no station-specific parameters are set, the hardware of the CPU or network
module is faulty.
Please consult your local Mitsubishi representative.
Perform Write to PLC on the network parameters for the control station again.
If the error reoccurs, the hardware of the CPU or network module is faulty.
Please consult your local Mitsubishi representative.
Set parameters suitable for the sub control station, or activate it as a control
station.
Review and reset the parameters for the master and sub master stations.
If the error reoccurs, the hardware of the CPU or network module is faulty.
Please consult your local Mitsubishi representative.
Set "with data link by the sub control station when the control station is down."
On the network parameter at control station, set the paring setting on the
Redundant CPU or unset the paring setting on all the CPUs other than the
Redundant CPU.
Match the network type set for the normal station with the one set for the control
station.
The hardware of the CPU or network module is faulty.
Please consult your local Mitsubishi representative.
If the data link is stopped under all station specification, start it by all station
specification.
If the data link is stopped under specific station specification, start it from the
station, or forcibly start it.
Start the data link from the station where it was discontinued, or forcibly start it.
The cable is faulty, or the hardware of the network module is faulty.
If a communication error has occurred, review the cable.
If not, the hardware of the network module is faulty.
Please consult your local Mitsubishi representative.
Check the status of the control station and of the remote master station (to see
if resetting or an error occurs in the middle of the operation).
Check the status of the control station and of the remote master station (to see
if resetting or an error occurs in the middle of the operation).
Register link parameters
Correct the contents of SW0000.
Corrective action
station-specific parameters for the sending range
station-specific parameters for the sending range
MELSEC-Q
8 - 40