APPENDICES
No.
Name
2
Data linking stop request
SW004A
station
(74)
2
SW004B
Host CPU status
(75)
2
Data linking start status
SW004D
(host)
(77)
2
Data linking stop status
SW004F
(host)
(79)
2
Data linking start status
SW0051
(entire system)
(81)
2
Data linking stop status
SW0053
(entire system)
(83)
SW0054
Parameter information
(84)
2: Valid only when SB0047 is off. When it turns on (error), the last data are retained.
App - 19
Table 3 Link special register (SW) list (Continued)
Description
Stores the station that stopped the host data linking. (Valid when
the SW0049 is 1.)
b15 b14 to
b7 b6 b5 b4 b3
SW004A
0
to
0
0: Station number designated
1: All stations designated
b0 to b6 store 7D
if a data link stop request is received from the
H
remote master station/multiplexed remote master station.
Indicates the CPU status of the host.
0
: Normal
Other than 0 : Abnormal (For the error codes, refer to
Section 8.3 or the "Error Code" chapter of
QCPU User's Manual (Hardware Design,
Maintenance and Inspection).)
Stores the result of starting cyclic transmission with Link startup
(host) (SB0000).
0
: Normal
Other than 0 : Abnormal (refer to the error codes in Section 8.3)
Stores the result of stopping cyclic transmission with Link stop
(host) (SB0001).
0
: Normal
Other than 0 : Abnormal (refer to the error codes in Section 8.3)
Stores the result of starting cyclic transmission with System link
startup (SB0002).
0
: Normal
Other than 0 : Abnormal (refer to the error codes in Section 8.3)
Stores the result of stopping cyclic transmission with System link
stop (SB0003).
0
: Normal
: Abnormal (refer to the error codes in Section
Other than 0
8.3)
At the PLC to PLC network.
Stores the parameter information.
(When the SB0054 and SB0055 are off.)
b15 b14
to
b2 b1 b0
0
to
0
MELSECNET/H
0: Not designated
1: Designated
(When the SB0055 is on.)
b15
b4
b3
0
to
0
0
1
When remote I/O net
Stores the parameter information.
(When the SB0054 and SB0055 are off.)
to
b15
b3
to
0
0
b2 b1 b0
0: Host 1 to 64: Station number
Type
00: Use only common parameters
01: Common parameters + station
specific parameters
10: Use only default parameters
11: Default parameters + station
specific parameters
b2 b1 b0
= 0F
: Parameter error
1
1
1
H
Check the error code in the SW055.
b2 b1 b0
0
0
Intelligent function
module parameter
0: No
1: Yes
MELSEC-Q
Availability
Remote
Control
Normal
master
station
station
station
Optical Coaxial Optical Coaxial Optical Coaxial Optical Coaxial
Remote I/O
station
App - 19