(b) Checking data link status of the host
1)
Link scan time etc., can be checked in SW005A to SW005B and
SW006B to SW006D.
2)
If an error occurs to data link, either of the following link special relays
(SB) will be turned ON.
• Baton pass status (host) (SB0047)
• Host data link status (SB0049)
3)
The cause of an error is stored in the following link special registers
(SW).
• Baton pass status (host) (SW0047)
• Cause of baton pass interruption (SW0048)
• Cause of data link stop (SW0049)
Description
No.
SW0047
Baton pass status (host)
SW0048
Cause of baton pass interruption
SW0049
Cause of data link stop
SW005A
Maximum baton pass station
SW005B
Maximum cyclic transmission station
SW006B
Maximum link scan time
SW006C
Minimum link scan time
SW006D
Current link scan time
MELSEC-Q