Operation

Basic Operation

The ST 40A system is very easy to adjust and operate. The following instructions
direct the operator to adjust temperature settings to levels that are arbitrary to
familiarize the operator with the system. The illustrations depict temperature in °C.
1. Insure that the system is properly prepared for operation. Refer to
the "Set-Up" portion of this manual. The handpiece selected for your
application should be connected to the unit. Refer to the Tip
Selection & Use section of this manual for more detailed information
on selection of the proper tip, handpiece and temperature options for
your particular application.

Digital Readout Operation

2. The Digital Readout provides a 2 line LCD
display of the temperature information.
The Digital Readout will show:
a) The software version of the system
power source for 2 seconds on initial
power up.
b) Temperature display in °C or °F
(programmable in Set-Up Mode).
c) The Operating Tip Temperature
("Temp = XXX") and the Set Tip
Temperature ("Set Temp = XXX").
d) The Operating Tip Temperature when
it stabilizes. The Set Tip Temperature
will disappear and only the Operating
Tip Temperature display will remain.
The system is now in Temperature
Display Mode (normal operation).
20
C
XXX
C
XXX
C
XXX