Pace ST 40A Operation & Maintenance Manual page 26

Table of Contents

Advertisement

Operation
8. Immediately press the Offset Key to
exit the Tip Offset Mode and enter the
new Tip Offset Constant into the
system
memory.
NOTE - "**" appears on the Digital Readout
if a Tip Offset Constant value greater than
0 (the default) has been stored in system
memory. Refer to "Auto Tip Temperature
Compensation" for a complete discussion
of Tip Temperature Offset function.
9. Press the Set Key. This is Tip Temperature
Set Mode. As received from the factory,
the Digital Readout will display "Set Temp
= OFF". If the Set Key is immediately
pressed again, or if no other operation
occurs within 5 seconds, the Digital
Readout will revert to the Temperature
Display Mode (normal operation).
10. If the Digital Readout reverts to the
Temperature Display Mode (normal
operation), press the Set Key once to
enter Tip Set Mode. Immediately press
and hold the Scroll Up ( ) Key.
Observe as the displayed Set Tip
Temperature increases first in 1°, then in
10° increments (°C or °F). Release the
key when the Digital Readout reads
316°C (or 600°F).
Immediately press the Set Key once
again. Observe the Digital Readout as
the Operating Tip Temperature reaches
316°C (or 600°F). The Digital Readout
will display both the Set Tip Temperature
and the (true) Operating Tip Temperature.
When the Operating Tip Temperature
reaches the Set Tip Temperature and
stabilizes, only the Operating Tip
Temperature will be displayed.
24
0 2 8
C
XXX
C
XXX
C
XXX
0 2 8
C
3 1 6
C
3 1 6