Operation; Variable Temperature Control; Temperature Dial Lock; Led Operation - Pace SODRTEK ST 25 Operation And Maintenance Manual

Soldering system
Hide thumbs Also See for SODRTEK ST 25:
Table of Contents

Advertisement

Operation

Variable Temperature Control

Adjust the Variable Temperature Control Knob to the desired temperature
setting. Notice that the control panel has an outer graphic scale denoting
temperature in °C (Celsius) and an inner graphic scale denoting temperature in
°F (Fahrenheit). These numerical scales denote the set tip temperature times
100 (e.g., "3" on the outer scale is 3 x 100 or 300°C).
Temperature/Dial Lock
The Variable Temperature Control Knob can be locked in position to avoid accidental or unauthorized
changes of the temperature setting.
1. Adjust the Temp. Control Knob to the desired temperature setting.
2. Using the Temp. Locking Key (hex key supplied with system), tighten
the set screw on the Temp. Locking Ring closest to the front panel.

LED Operation

The Green colored LED on the power source front panel indicates System Status and Power
Receptacle output status (LED OFF, ON or Flashing).
LED Full On - Continuous power is being delivered to the handpiece. This
condition is evident when the system is first powered up (handpiece heater
cold) or the Variable Temperature Control setting is increased.
LED Flashing - Indicates that the set tip temperature (as set on the
Variable Temperature Control) has been reached. Power to the handpiece
is cycling Off and On to maintain set temperature.
LED Off - No power is being delivered to the handpiece heater. This condition is evident for a
short period of time when set temperature is reached and stabilizing or if the Variable
Temperature Control setting is decreased.
handpiece (see Corrective Maintenance section). Also, if no handpiece is connected to the
power source, the LED will not illuminate.

Temperature Dial Adjustment

The ST 25 system is tested for temperature accuracy at the factory and can be
checked for calibration according to PACE requirements. Also, a temperature setting
normally used by the operator can be adjusted to the precise temperature indicated on
the Dial/Display. No internal adjustments can be made to the power supply. To verify
calibration of the Temperature selection dial, perform the following procedure.
1. Install a tip with an embedded thermocouple into the handpiece connected to the system.
Tips with K type thermocouples are available from PACE.
2. Connect the thermocouple assembly to an appropriate temperature meter.
3. When set fully counterclockwise, the pointer of the Variable Temperature
Control knob will align to the Calibration Mark as shown. With the system
turned on, adjust the Variable Temperature Control to obtain a stable tip
temperature of 300°C (for PACE factory specifications) or the temperature
setting normally used by the operator.
If the temperature displayed on temperature meter is within ±15°C (27°F),
perform steps 4 thru 6 to obtain a precise reading. If the temperature is off by more than
If the LED never illuminates, check for a faulty
w w w . e k t
2
. c o m

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sodrtek st 25e5050-0530

Table of Contents