11. Press the Set Key once to enter the Tip
Temperature Set Mode. Immediately
press & hold the Scroll Down ( ) Key.
Observe as the displayed Set Tip
Temperature decreases first in 1° and then
in 10° increments (°C or °F). Release the
key when the Digital Readout displays
288°C (550°F). Immediately press the
Set Key once again.
12. Immediately press the Set Key (or wait 6
seconds) to exit the Tip Temperature Set
Mode and observe the Operating Tip
Temperature decrease to 288°C (550°F).
13. The system will retain the stored Set Tip
Temperature and Tip Offset Constant
even when power is removed.
14. Turn the Power Switch to the OFF ("0")
position. Turn the switch back to the ON
("1") position.
15. Press the Set Key. Notice that the system
has retained the stored Set Tip
Temperature and Tip Offset Constant in
memory. Immediately press the Set Key
once again to exit Tip Temperature Set
Mode.
16. In order to prevent a handpiece/tip
combination from inadvertently operating
at an incorrect Tip Temperature, the
system will not retain a stored Tip Offset
Constant if a handpiece is disconnected
with power on. The Tip Offset Constant
will return to the default value of "0" (for
°C or °F). Disconnect the handpiece.
Reconnect the handpiece.
Operation
C
2 8 8
0 2 8
C
2 8 8
C
2 8 8
0 2 8
25