Operation; Password; Front Panel Selections - Pace ST325E Operation And Maintenance Manua

Soldering/desoldering system
Table of Contents

Advertisement

4. The LCD will flash, displaying "Ent Auto Temp" and "A -
Temp = ___ °."
NOTE: The "A - Temp = ___ ° " will display the current
temperature that is set in the Manual Mode (e.g.,
"A -Temp = 700 °F").
5. Use the Scroll Keys (
temperature and press the Select Button to accept the entry. If the Scroll Keys are not pressed
for a duration of 5 seconds, the LCD will return to the flashing of the "Ent Auto Temp" and "A -
Temp = ___ °."
6. The LCD will flash, displaying "Auto Blower = 7" and "Ent Auto Blower."
NOTE: The "Auto Blower = ___ " will display the current temperature that is set in the Manual
Mode (e.g., "Auto Blower = 7").
7. Use the Scroll Keys (
accept the entry. If the Scroll Keys are not pressed for a duration of 5 seconds, the LCD will
return to the flashing of the "Auto Blower = 7" and "Ent Auto Blower."
8. Press the Cycle Button to start the Calibration Process.
NOTE: Anytime during this operation the Vacuum Button can be pressed to
escape the process.
9. Once the process is completed, the LCD will display "Save Offset?" At this time,
the offset may be saved by pressing the Up Button (
Mode may be exited by pressing the Vacuum Button on the handpiece. Either
selection will exit the Offset Calibration Mode and place the system into the
previously used menu for regular operation.
NOTE: If during the procedure the LCD displays " Auto Cal Error," repeat the
Auto Calibration Procedure again.

Operation

The PACE ST 325 unit is easy to operate and can be quickly set up for operation. The following steps
provide basic guidelines for rework using the PACE ST 325.

Password

The Password feature of the ST 325 system, when activated, will prevent unauthorized alteration of
stored system temperature parameters and custom settings (refer to the "Set Up Mode Section"). If a
Password has been installed, the LCD Display will display an instruction to enter the Password (a 4
digit number) when a setting change is attempted. Entry of the correct Password at this point will
allow the operator to proceed with the desired changes.

Front Panel Selections

The front panel on the ST 325 contains a four button interface which allows easy operation of the
system, including creating and modifying profiles. There are four different selections within the
Mode column. They are Manual, Timed Install, Timed Removed, and PC Control. The
following pages will provide step-by-step procedures for the various modes.
©2013 PACE Inc., Southern Pines, NC
All Rights Reserved
) to select the desired
) to select the desired blower speed and press the Select Button to
) or the Offset Calibration
Page 13 of 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

St 3255050-0537