Basic Operation

Definitions

Please familiarize yourself with the definitions of each of the following terms.
Auto-Off: Safety feature that turns the power to the irons off after the system has entered Temperature
Setback. (1-90 minutes, settable in 1-minute increments)
Normal Operation: Normal operating mode of the system in which the Operating Tip Temperatures are
displayed.
Password: The Password feature of the system will prevent unauthorized alteration of stored system
parameters and features. If a Password has been installed, the display will show an instruction to enter
the password. Enter the four-digit number by using the scroll up /down keys on the system front panel.
Setup Mode: The interface used to program the system features and parameters (e.g., temperature
limits, password, setback time).
Set Temperature: The operator selected tip temperature stored in the system memory.
Temperature Adjust Mode: Mode of operation where the Set Temperature may be adjusted.
Temperature SetBack: System feature that will "set back" the temperature of the iron to a lower value
after a set period of inactivity has been detected by the system. The SetBack temperature and time are
both customizable by the user, refer to the section on Customizing Your System for more information.

Operation

1. Ensure the Set-Up procedure has been performed. Check the
following:
Handpiece connection to the power source.
Proper Tip-Heater Cartridge or tip is installed in each
handpiece.
Power cord is connected to both an appropriate AC
supply and the unit.
2. Turn the Power Switch On ("I").
3. The Set Temperature will be displayed after the brief start-up sequence.
4. Adjust the tip temperature by pressing and holding Scroll Up Key ( ) or Scroll Down Key ( ) to adjust
the temperature and the Program Key ( ) to switch channels. The Set Temperature increases/decreases
in 1° increments at first, then increments of 10°. Release the key when desired temperature has been set.
NOTE: The Set Temperature can only be adjusted within the upper and lower temperature limits. If the
lower limit is reached, the display will read "OFF". Temperature limits can be adjusted in the Set-Up
menu. Refer to section Customizing Your System for more information.

LED Indicator Meanings

The Amber, Red and Green tri-colored LEDs on the front panel of the power source indicate the status of
attached handpiece(s) as follows.
LED is Green - Indicates the set tip temperature has been reached for this channel. Power to the
handpiece is cycling to maintain the temperature set point.
LED is Steady Amber - Continuous power is being delivered to the handpiece. This condition is evident
when the system is first powered up (handpiece heater cold) or the temperature setting is increased.
©2022 PACE Inc., Vass, North Carolina, All Rights Reserved