Temperature Setback; Activation; Operation - Pace ST 40A Operation & Maintenance Manual

Table of Contents

Advertisement

Temperature Setback

To preserve tip life and save energy, the ST 40A system can be programmed to
automatically set back its Tip Temperature to 177°C (350°F) after a selected period
of handpiece inactivity (adjustable 5-120 minutes in Set-Up Mode). As received
from the factory, this feature is enabled. Refer to the "Set-Up Mode" section of this
manual to disable or adjust the time-out period of this feature. The operator can also
force the system into Temperature Setback. The Auto Off Safety feature is also
enabled automatically when Temperature Setback is enabled.
If the Set Tip Temperature is less than 177°C (350°F), the system will remain
at the lower temperature in Temperature Setback.

Activation

There are two ways in which the system will activate the Temperature Setback feature.
1. AUTOMATIC ACTIVATION - The system memory can be programmed
so that the system will automatically activate Temperature Setback after a
selected period (5-120 minutes) of handpiece inactivity. See the "Set-Up
Mode" section for details on programming this feature.
2. MANUAL ACTIVATION - The operator can manually force the system
to place the system in Temperature Setback by performing the following
procedure.
a) Press and hold the Scroll Down ( ) Key.
b) Press the Scroll Up ( ) Key.
c) Release both keys.

Operation

Temperature Setback is indicated by the following.
1. The hour glass icon at the top left corner of the Digital Readout will start
flashing 1 minute before entering Temperature Setback and continue to
flash while in Temperature Setback.
2. The Operating Temperature will stabilize at 177°C (350°F) unless the Set
Tip Temperature is lower (see NOTE above).
3. The bottom line of the Digital Readout will display the time remaining to
Auto Off in hours and minutes.
NOTE
Operation
XXX