4.3.2

Recommended order of creation

After a new project has been created, the required components must be inserted into the
device configuration – and in most cases, also specified. If an optimum sequence is
maintained when inserting the components, then the inserted components are also
automatically wired.
Recommended order:
1. Drive
2. Infeed unit
3. Motor Module
4. Motor
5. Encoder (measuring system)
6. Supplementary system components (Terminal Modules, Terminal Board)
If this sequence is not complied with (e.g. because the infeed unit is only subsequently
added), then it is possible that Startdrive does not automatically wire the components. In this
case, you must manually establish the wiring in the device view (see Chapter "Editing a
DRIVE-CLiQ connection (Page 70)").
Note
For several motors, when creating the motor, an encoder not specified in the device view is
simultaneously created. In this case, a separate encoder no longer has to be created.