Terminal Modules; Terminal Module Tm15 - Siemens Sinamics S120 Comissioning Manual

With startdrive
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

5.2.4

Terminal Modules

5.2.4.1

Terminal Module TM15

Table 5- 15
Meanings of the LEDs on the Terminal Module TM15
LED
Color
READY
-
Green
Orange
Red
Green/
red
Green/
orange
or
Red/
orange
The parameters for activating component recognition using LEDs can be taken from the following reference:
1)
Reference: /LH1/ SINAMICS S120/S150 List Manual
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
Status
Off
The electronics power supply is missing or outside the per-
missible tolerance range.
Continuous
The component is ready for operation. Cyclic DRIVE-CLiQ
light
communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
The LED is activated irrespective of whether the correspond-
ing messages have been reconfigured.
Flashing
Firmware is being downloaded.
light 0.5 Hz
Flashing
Firmware download is complete. The system waits for
light 2 Hz
POWER ON.
Flashing
Component recognition via LED is activated
light
Note:
Both options depend on the LED status when component
recognition is activated.
Description, cause
.
1)
Diagnostics
5.2 Diagnostics using LEDs
Remedy
Remove and
acknowledge the
fault.
Carry out a POWER
ON.